To furnish the ever rising requirements and necessities of
our patrons, we have brought forward an extensive class plethora
of AHU Filter, HEPA Filter, Evaporative Cooling Pad, PVC Fills etc.
In conformation with the standards and quality strategies defined by
the industry, all our products are accredited and appreciated for their
long-lasting nature.
Aerosense Magnehelic Gauge Wholesale Suppliers India.
Supplier from Delhi, we offer Differential Pressure such
as Digital Differential Pressure Gauge, Digital Differential
Pressure Controller, Differential Pressure Transmitter, Differential
Pressure Gauge, Scalable Differential Pressure Transmitter, Intrinsically
Safe Differential Pressure Transmitter and many more items.
Aerosense Model ASGC-00 Inch Differential Pressure Gauge Range 0.125-0-0.125 INCH
Product Details:
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 %
Temperature
-6.67 to 60'C
Weight
510 Gm
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Process Connection
1/8" Female
Pressure Limits
-0.677 bar to 1.034 bar
Aerosense Model Asgc -01 Inch Differential Pressure Gauge Ranges 0.5-0-0.5 Inch
Product Details:
Display Type
Analog
Brand
Aerosense
Size
4" (101.6 mm)
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Model No
ASGC-01
Usage Application
Filter Monitoring,Blower Vacuum Monitoring Fan Pressure Indication,Duct,Room Or Building Press
Weight
510 Gm
Aerosense Model ASGC-01 INCH Differential Pressure Gauge Range 0.5-0-0.5 INCH
Model ASGC-01
Range 0.5-0-0.5 INCH
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineersindia.in
Aerosense Model Asgc -02 Inch Differential Pressure Gauge Ranges: 1-0-1 Inch
Product Details:
Model Number
ASGC-02
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 %
Temperature
-6.67 to 60'C
Weight
510 Gm
Size
4" (101.6 mm)
Mounting
Vertically
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Aerosense Model ASGC-02 INCH Differential Pressure Gauge Range 1-0-1 INCH Model ASGC-02 Range 1-0-1 INCH
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineer.info
Aerosense Model Asgc -04 Inch Differential Pressure Gauge Ranges: 2-0-2 Inch
Product Details:
Model Number
ASGC-04
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Temperature
-6.67 to 60'C
Weight
510 Gm
Dial Size
4 Inch
Dial Shape
Round
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Aerosense Model ASGC-04 INCH Differential Pressure Gauge Range 2-0-2 INCH
Model ASGC-04
Range 2-0-2 INCH
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineer.co.in
Aerosense Model Asgc -10 Inch Differential Pressure Gauge Ranges: 5-0-5 Inch
Product Details:
Minimum Order Quantity
10 Piece
Model Number
ASGC-10
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 %
Temperature
-6.67 to 60'C
Weight
510 Gm
Dial Shape
Round
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Aerosense Model ASGC-10 INCH Differential Pressure Gauge Range 5-0-5 INCH
Model ASGC-10
Range 5-0-5 INCH
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Aerosense Model Asgc -20 Inch Differential Pressure Gauge Ranges: 10-0-10 Inch
Product Details:
Model Number
ASGC -20
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 %
Temperature
20 to 140"F* (-6.67 to 60'C)
Weight
510 Gm
Dial Size
101.6 mm
Dial Shape
Round
Mounting
Vertically
Aerosense Model ASGC-20 INCH Differential Pressure Gauge Range 10-0-10 INCH
Model ASGC-20
Range 10-0-10 INCH
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineers.co.in
Aerosense Model Asg -50 Cm Differential Pressure Gauge Ranges 0-50 Cm
Product Details:
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Weight
510 Gm
Dial Size
4 Inch
Dial Shape
Round
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Aerosense Model ASG-50CM Differential Pressure Gauge Range 0-50 CM of Water
Model ASG-50CM Range 0-50 CM of Water
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineer.info
Aerosense Model Asg -80 Cm Differential Pressure Gauge Ranges 0-80 Cm
Product Details:
Minimum Order Quantity
10 Piece
Model Number
ASG -80 CM
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Scale Range
0-80 CM Of Water
Weight
510 Gm
Dial Size
4" (101.6 mm)
Mounting
Vertically
Aerosense Model ASG-80CM Differential Pressure Gauge Range 0-80 CM of Water Model ASG-80CM
Range 0-80 CM of Water
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi
Additional Information:
Production Capacity: http://www.dpengineer.info
Delivery Time: http://www.dpengineersindia.in
Packaging Details: http://www.dpengineersindia.in
Aerosense Model Asg -100 Cm Differential Pressure Gauge Ranges 0-100 Cm
Product Details:
Model Number
ASG-100CM
Usage/Application
Fan Pressure Indication,Duct,Room Or Building Pressures,Clean Room Positive Pressure Indication
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 5
Temperature
-6.67 to 60'C
Weight
510 Gm
Dial Size
4 Inch
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Aerosense Model ASG-100CM Differential Pressure Gauge Range 0-100 CM of Water
Model 0-100 CM of Water
Range 0-100 CM
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineer.info
Aerosense Model Asg -150 Cm Differential Pressure Gauge Ranges 0-150 Cm
Product Details:
Minimum Order Quantity
10 Piece
Model Number
ASG-150CM
Usage/Application
Fan Pressure Indication,Duct,Room Or Building Pressures,Clean Room Positive Pressure Indication
Display Type
Analog
Brand
Aerosense
Scale Range
0-150 CM Of Water
Dial Size
101.6 mm
Mounting
Vertically
Aerosense Model ASG-150CM Differential Pressure Gauge Range 0-150 CM of Water
Model ASG-150CM
Range 0-150 CM of Water
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Production Capacity: http://www.dpengineer.info
Delivery Time: http://www.dp-engineers.com
Packaging Details: http://www.dpengineers.co.in
Aerosense Model Asgc -30 Inch Differential Pressure Gauge Ranges 15-0-15 Inch
Product Details:
Minimum Order Quantity
10 Piece
Model Number
ASGC-30
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 %
Temperature
-6.67 to 60'C
Weight
510 Gm
Dial Size
4" (101.6 mm)
Dial Shape
Round
Mounting
Vertically
Aerosense Model ASGC-30 INCH Differential Pressure Gauge Range 15-0-15 INCH
Model ASGC-30
Range 15-0-15 INCH
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Production Capacity: http://www.dpengineers.co.in
Delivery Time: http://www.dpengineers.in
Packaging Details: http://www.dpengineers.co.in
Aerosense Model Asg -25 Cm Differential Pressure Gauge Ranges 0-25 Cm
Product Details:
Model Number
ASG-25CM
Usage/Application
Fan Pressure Indication,Duct,Room Or Building Pressures,Clean Room Positive Pressure Indication
Display Type
Analog
Brand
Aerosense
Weight
510 Gm
Dial Size
4 Inch
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Pressure Limits
-0.677 bar to 1.034 bar
Aerosense Model ASG-25CM Differential Pressure Gauge Range 0-25 CM of Water
Model ASG-25CM
Range 0-25 CM of Water
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineerindia.in
Aerosense Model Asgc -0 Inch Differential Pressure Gauge Ranges 0.25-0-0.25 Inch
Product Details:
Model Number
ASGC-0
Usage/Application
Fan Pressure Indication,Duct,Room Or Building Pressures,Clean Room Positive Pressure Indication
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 %
Weight
510 Gm
Dial Size
101.6 mm
Pressure Limits
-0.677 bar to 1.034 bar
Tempreture
-6.67 to 60'C
Aerosense Model ASGC-0 INCH Differential Pressure Gauge Range 0.25-0-0.25 INCH
Model ASGC-0 Range 0.25-0-0.25 INCH
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Aerosense Model Asg - 15cm Differential Pressure Gauge Ranges 0-15 Cm
Product Details:
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Dial Shape
Round
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Pressure Limits
-0.677 bar to 1.034 bar
Aerosense Model ASG-15CM Differential Pressure Gauge Range 0-15 CM of Water
Model ASG-15CM
Range 0-15 CM of Water
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineerindia.in
Aerosense Model Asg - 200cm Differential Pressure Gauge Ranges 0-200 Cm
Product Details:
Model Number
ASG-200CM
Usage/Application
Fan Pressure Indication,Duct,Room Or Building Pressures,Clean Room Positive Pressure Indication
Display Type
Analog
Brand
Aerosense
Scale Range
0-200 CM Of Water
Accuracy
+ / - 2 %
Temperature
-6.67 to 60'C
Weight
510 Gm
Dial Size
4 Inch
Dial Shape
Round
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Aerosense Model ASG-200CM Differential Pressure Gauge Range 0-200 CM of Water
Model ASG-200CM
Range 0-200 CM of Water
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineerindia.com
Aerosense Model Asg - 250cm Differential Pressure Gauge Ranges 0-250 Cm
Product Details:
Minimum Order Quantity
10 Piece
Model Number
ASG-250CM
Usage/Application
Fan Pressure Indication,Duct,Room Or Building Pressures,Clean Room Positive Pressure Indication
Display Type
Analog
Brand
Aerosense
Scale Range
0-250 CM Of Water
Weight
510 Gm
Dial Size
101.6 mm
Mounting
Vertically
Aerosense Model ASG-250CM Differential Pressure Gauge Range 0-250 CM of Water
Model ASG-250CM
Range 0-250 CM of Water
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi
Additional Information:
Production Capacity: http://www.dpengineerindia.com
Delivery Time: http://www.dpengineersindia.in
Packaging Details: http://www.dpengineersindia.in
Aerosense Model Asg - 300cm Differential Pressure Gauge Ranges 0-300 Cm
Product Details:
Model Number
ASG-300CM
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense Singapore
Dial Shape
Round
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Pressure Limits
-0.677 bar to 1.034 bar
Aerosense Model ASG-300CM Differential Pressure Gauge Range 0-300 CM of Water
Model ASG-300CM
Range 0-300 CM of Water
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineer.co.in
Aerosense Model Asgc - 6mm Differential Pressure Gauge Ranges 3-0-3mm
Product Details:
Model Number
ASGC-6MM
Usage/Application
Fan Pressure Indication,Duct,Room Or Building Pressures,Clean Room Positive Pressure Indication
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 %
Weight
510 Gm
Dial Size
4" (101.6 mm)
Mounting
Vertically
Pressure Limits
-6.67 to 60'C
Aerosense Model ASGC-6MM Differential Pressure Gauge Range 3 -0-3 MM
Model ASGC-6MM
Range 3 -0-3 MM
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineer.in
Aerosense Model Asgc - 10mm Differential Pressure Gauge Ranges 5-0-5mm
Product Details:
Model Number
ASGC-10MM
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2%
Temperature
-6.67 to 60'C
Weight
510 Gm
Dial Size
4" (101.6 mm)
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Pressure Limit
-0.677 bar to 1.034 bar
Aerosense Model ASGC-10MM Differential Pressure Gauge Range 5 -0-5 MM Model ASGC-10MM
Range 5 -0-5 MM
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineerindia.com
Aerosense Model Asgc - 20mm Differential Pressure Gauge Ranges 10-0-10mm
Product Details:
Model Number
ASGC-20MM
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 %
Temperature
-6.67 to 60'C
Weight
510 Gm
Dial Size
4 Inch
Pressure Limits
-0.677 bar to 1.034 bar
Aerosense Model ASGC-20MM Differential Pressure Gauge Range 10 -0-10 MM
Model ASGC-20MM
Range 10 -0-10 MM
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineers.co.in
Aerosense Model Asg - 20cm Differential Pressure Gauge Ranges 0-20cm
Product Details:
Model Number
ASG-20CM
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,Fan Pressure Indication,Duct,Room Or Building Pressure
Display Type
Analog
Brand
Aerosense
Scale Range
0-20 CM Of Water
Accuracy
+ / - 2 %
Temperature
-6.67 to 60'C
Weight
510 Gm
Dial Size
4 Inch
Mounting
Vertically
Aerosense Model ASG-20CM Differential Pressure Gauge Range 0-20 CM of Water
Model ASG-20CM
Range 0-20 CM of Water
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 %
Weight
510 Gm
Size
4 Inch
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Shape
Round
Aerosense Model ASGC-1KPA Differential Pressure Gauge Range .5-0-.5 KPA
Model ASGC-1KPA
Range .5-0-.5 KPA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineerindia.com
Aerosense Model Asgc - 2kpa Differential Pressure Gauge Ranges 1-0-1kpa
Product Details:
Model Number
ASGC - 2KPA
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Temperature
-6.67 to 60'C
Weight
510 Gm
Dial Shape
Round
Size
101.6 mm
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Aerosense Model ASGC-2KPA Differential Pressure Gauge Range 1-0-1KPA
Model ASGC-2KPA
Range 1-0-1KPA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineers.in
Aerosense Model Asgc - 60pa Differential Pressure Gauge Ranges 30-0-30pa
Product Details:
Minimum Order Quantity
10 Piece
Model Number
ASGC-60PA
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 %
Temperature
20 to 140"F* (-6.67 to 60'C)
Weight
510 Gm
Size
101.6 mm
Aerosense Model ASGC-60PA Differential Pressure Gauge Range 30-0-30 PA
Model ASGC-60PA
Range 30-0-30 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Production Capacity: http://www.dpengineerindia.com
Delivery Time: http://www.dpengineersdelhi.co.in
Packaging Details: http://www.dpengineers.in
Aerosense Model Asgc - 100pa Differential Pressure Gauge Ranges 50-0-50pa
Product Details:
Model Number
ASGC - 100PA
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2 %
Weight
510 Gm
Size
4 Inch
Pressure Limits
-20 in Hg to 15 psig
Temprature
-6.67 to 60'C
Aerosense Model ASGC-100PA Differential Pressure Gauge Range 50-0-50 PA Model ASGC-100PA Range 50-0-50 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineersindia.in
Aerosense Model Asgc - 2.5kpa Differential Pressure Gauge Ranges 1.25-0-1.25kpa
Product Details:
Model Number
ASGC-2.5KPA
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Weight
510 g
Size
4 Inch
Pressure Limits
-0.677 bar to 1.034 bar
Temprature Limits
20 to 140"F* (-6.67 to 60'C)
Aerosense Model ASGC-2.5KPA Differential Pressure Gauge Range 1.25-0-1.25 KPA
Model ASGC-2.5KPA
Range 1.25-0-1.25 KPA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Delivery Time: http://www.dpengineersdelhi.co.in
Packaging Details: http://www.dpengineerindia.com
Aerosense Model Asgc - 3kpa Differential Pressure Gauge Ranges 1.5-0-1.5kpa
Product Details:
Model Number
ASGC-3KPA
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Accuracy
+ / - 2%
Temperature
-6.67 to 60'C
Weight
510 g
Size
101.6 mm
Pressure Limits
-0.677 bar to 1.034 bar
Aerosense Model ASGC-3KPA Differential Pressure Gauge Range 1.5-0-1.5 KPA
Model ASGC-3KPA
Range 1.5-0-1.5 KPA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Aerosense Model Asgc - 4cm Differential Pressure Gauge Ranges 2-0-2cm
Product Details:
Model Number
ASGC-4CM
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Weight
510 g
Size
101.6 mm
Mounting
Vertically
Pressure Limits
-0.677 bar to 1.034 bar
Shape
Round
Aerosense Model ASGC-4CM Differential Pressure Gauge Range 2-0-2 CM
Model ASGC-4CM
Range 2-0-2 CM
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Aerosense Model ASGC-10CM Differential Pressure Gauge Range 5-0-5 CM
Model ASGC-10CM Range 5-0-5 CM
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineerindia.com
Aerosense Model Asgc - 30cm Differential Pressure Gauge Ranges 15-0-15cm
Product Details:
Model Number
ASGC - 30 CM
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Measuring Range
15 - 0 - 15 CM
Brand
Aerosense
Accuracy
+-2%
Temperature
-6.67 to 60'C
Weight
510 g
Dial Shape
Round
Size
4" (101.6 mm)
Aerosense Model ASGC-30CM Differential Pressure Gauge Range 15-0-15 CM
Model ASGC-30CM
Range 15-0-15 CM
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Delivery Time: http://www.dpengineers.in
Packaging Details: http://www.dpengineer.co.in
Aerosense Model Asgc - 60npa Differential Pressure Gauge Ranges 10-0-50 Pa
Product Details:
Minimum Order Quantity
10 Piece
Model Number
ASG - 60 NPA
Usage/Application
Exhaust Stack Air Flow Monitoring,Clean Room Fresh Air Supply,Hvac Air Velocity Measurements
Display Type
Analog
Measuring Range
10 - 0 - 50 PA
Brand
Aerosense
Accuracy
+-2%
Weight
510 g
Dial Size
4" (101.6 mm)
Mounting
Vertically
Aerosense Model ASG-60NPA Differential Pressure Gauge Range 10-0-50 PA
Model ASG-60NPA Range 10-0-50 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Production Capacity: http://www.dpengineersindia.in
Delivery Time: http://www.dpengineersindia.in
Packaging Details: http://www.dpengineerindia.in
Aerosense Model Asg - 60pa Differential Pressure Gauge Ranges 0-60 Pa
Product Details:
Model Number
ASG-60PA
Usage/Application
Exhaust Stack Air Flow Monitoring,Clean Room Fresh Air Supply,Hvac Air Velocity Measurements
Display Type
Analog
Measuring Range
0-60 PA
Brand
Aerosense
Accuracy
+-2%
Weight
510 g
Size
4" (101.6 mm) diameter dial face
Mounting
Vertically
Pressure Limits
-0.677 bar to 1.034 bar
Aerosense Model ASG-60PA Differential Pressure Gauge Range 0-60 PA
Model ASG-60PA
Range 0-60 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Delivery Time: http://www.dpengineerindia.com
Packaging Details: http://www.dpengineersindia.in
Aerosense Model ASG - 100 PA Differential Pressure Gauge Ranges 0-100 PA
Product Details:
Usage/Application
Exhaust Stack Air Flow Monitoring, Clean Room Fresh Air Supply, Hvac Air Velocity Measurements
Display Type
Analog
Brand
Aerosense
Model
ASG - 100 PA
Measuring Range
0-100 PA
Size
4" (101.6 mm)
Weight
510 g
Aerosense Model ASG-100PA Differential Pressure Gauge Range 0-100 PA
Model ASG-100PA
Range 0-100 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineer.info
Aerosense Model Asg - 125 Pa Differential Pressure Gauge Ranges 0-125 Pa
Product Details:
Model Number
ASG - 125 PA
Usage/Application
Exhaust Stack Air Flow Monitoring,Clean Room Fresh Air Supply,Hvac Air Velocity Measurements
Display Type
Analog
Brand
Aerosense
Measuring Range
0-125 PA
Diameter
4" (101.6 mm)
Weight
510 g
Dial Shape
Round
Aerosense Model ASG-125PA Differential Pressure Gauge Range 0-125 PA
Model ASG-125PA
Range 0-125 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineers.in
Aerosense Model Asg - 250 Pa Differential Pressure Gauge Ranges 0-250 Pa
Product Details:
Model Number
ASG-250PA
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Brand
Aerosense
Scale Range
0-250 PA
Temperature
-6.67 to 60'C
Weight
510 Gm
Dial Size
4" (101.6 mm)
Color
Black
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Mounting Orientation
Vertically
Aerosense Model ASG-250PA Differential Pressure Gauge Range 0-250 PA
Model ASG-250PA
Range 0-250 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineerindia.com
Aerosense Model Asg - 300 Pa Differential Pressure Gauge Ranges 0-300 Pa
Product Details:
Model Number
ASG-300PA
Usage/Application
Exhaust Stack Air Flow Monitoring, Clean Room Fresh Air Supply, Hvac Air Velocity Measurements
Display Type
Analog
Measuring Range
0 - 300 PA
Brand
Aerosense
Accuracy
+-2%
Diameter
4" (101.6 mm)
Weight
510 g
Shape
Round
Aerosense Model ASG-300PA Differential Pressure Gauge Range 0-300 PA
Model ASG-300PA
Range 0-300 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineersindia.in
Aerosense Model Asg - 500 Pa Differential Pressure Gauge Ranges 0-500 Pa
Product Details:
Minimum Order Quantity
10 Piece
Model Number
ASG-500PA
Usage/Application
Filter monitoring Blower Vacuum Monitoring Fan Pressure Indication Duct,Room or Building Pressures
Material
Aluminium
Connection
New
Measuring Range
0-500 PA
Brand
Aerosense Singapore
Case and Bezel
Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover
Weight
510 g
Dial Size
4" (101.6 mm) diameter dial face
Color
Black
Mounting
Diaphragm in vertical position. Consult factory for other position orientations.
Battery Included
No
Aerosense Model ASG-500PA Differential Pressure Gauge Range 0-500 PA
Model ASG-500PA
Range 0-500 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Production Capacity: http://www.dpengineersindia.in
Delivery Time: http://www.dpengineerindia.com
Packaging Details: http://www.dpengineers.in
Aerosense Model ASG - 750 PA Differential Pressure Gauge Ranges 0-750 PA
Product Details:
Brand
Aerosense
Measuring Range
0-750 PA
Model Number
ASG-750PA
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analig
Color
Black
Accuracy
+ / - 2 %
Temperature
-6.67 to 60'C
Weight
510 Gm
Size
4" (101.6 mm)
Dial Shape
Round
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Aerosense Model ASG-750PA Differential Pressure Gauge Range 0-750 PA
Model ASG-750PA
Range 0-750 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineerindia.com
Aerosense Model ASG -1000 PA Differential Pressure Gauge Ranges 0-1000 PA
Product Details:
Brand
Aerosense
Model Number
ASG - 200PA
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Accuracy
+ / - 2 %
Weight
510 Gm
Dial Size
4" (101.6 mm)
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Pressure Limits
-0.677 bar to 1.034 bar
Aerosense Model ASG-1000PA Differential Pressure Gauge Range 0-1000 PA
Model ASGC-1000PA Range 0-1000 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Delivery Time: http://www.dpengineersindia.in
Packaging Details: http://www.dpengineersindia.in
Aerosense Model ASG -200 PA Differential Pressure Gauge Ranges 100-0-100 PA
Product Details:
Brand
Aerosense
Model Number
ASG -200 PA
Usage/Application
Filter Monitoring,Blower Vacuum Monitoring,,Fan Pressure Indication,Duct,Room Or Building Press
Display Type
Analog
Color
Silver
Temperature
-6.67 to 60'C
Weight
510 Gm
Dial Size
4" (101.6 mm)
Housing Material
Die Cast Aluminum Case And Bezel With Acrylic
Aerosense Model ASGC-200PA Differential Pressure Gauge Range 100-0-100 PA
Model ASGC-200PA
Range 100-0-100 PA
Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.
Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.
Product Applications:
Filter monitoring
Blower Vacuum Monitoring
Fan Pressure Indication
Duct, Room or Building Pressures
Clean Room Positive Pressure Indication
Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.
Additional Information:
Packaging Details: http://www.dpengineerindia.in
Aerosense Series AVT Air Velocity Cum Temperature Transmitter
Product Details:
Usage/Application
Exhaust Stack Air Flow Monitoring,Clean Room Fresh Air Supply,Hvac Air Velocity Measurements
Model Name/Number
AVT-D-R
Voltage
250 VAC
Weight
220 Gram
Brand
Aerosense
Mounting
2 Screw Holes,4.0 mm
Probe Material
Stainless Steel
Size
45.7 x 12.7 mm
Velocity Accuracy
0-2 m/s
Aerosense Series AVT Air Velocity Cum Temperature Transmitter With Display And Relay
Model: AVT-D-R
Make - AEROSENSE Singapore
Series AVT Air Velocity cum Temperature Transmitter
Series AVT Air Velocity Transmitter is the ideal instrument for measurement of Air Velocity and Temperature. The field selectable ranges provides the versatility to be selected for several air flow applications. The optional LED produces a complete, low cost solution for local indication of air flow.
Product Applications:
Exhaust stack air flow monitoring
Clean room fresh air supply
HVAC air velocity measurements
Fan supply
Air Control in drying processes
Conformance: Meets the requirements for CE marking
Media compatibility: Dry air or non-aggressive gases